Technical characteristics ÌÅÒ-ÍRC (ÌÅÒ-ÍB, ÌÅÒ-HV, MET-HSD)

Overall dimensions, mm:
Length
Width
Height
 
70
50
82
Mass, g250
Applied force, N (kgf)9,8 (1)
Time of one measurement, sec2
Power supply1 AA battery
Time of measurements on one power supply set, hours60
Automatic power supply disconnection, sec60
Temperature range from.. to.. while in operation, °Ñ:-10 ... + 55
Relative humidity, %30 ... 80
Location and angle of hardness tester while testingAny (does not influence on measurement accuracy)
Indication on the display while testingMeasurement result
Number of current measurement
Indication on the display while calculation the average resultAverage result
Number of measurements
Roughness of tested surface, Ra2,5
Radius of curvature on tested surface not less than, mm5
Width of tested sample not less than, mm:1
Tester resources (minimum number of testings):200000
Processing of the results and connection to computer by USB portNo
Display highlightNo
Calibration by a customerNo
Changes archiveNo

Range and error of measurements:

Hardness tester name Hardness scale Measurement range Measurement error
ÌÅÒ-HRC Rockwell (scale "Ñ") 20 - 70 HRC ±1,5 HRC
MET-HB Brinell 75 - 650 HB ±10 HB
MET-HV Vickers 75 - 1000 HV ±12 HV
MET-HSD Shore 23 - 102 HSD ±2 HSD
© Centre "ÌÅÒ" +7 (495) 229-75-26, 506-90-38 E-MAIL